Mfg Part Number: GB3-A2A3A3-5-9 | Alternate P/N: GB3A2A3A359 | Manufacturer: Eaton Corp |
NSN : 5925-00-408-8847 | Item Name : circuit breaker | CAGE Code : 74193 |
FSC : 5925 Circuit Breakers |
Thank you for your interest in the Circuit Breaker parts we have in stock on Integrated Electronics Parts. This particular Eaton Corp item is listed alongside the NSN 5925-00-408-8847 and part number GB3-A2A3A3-5-9, allowing you to locate it quickly and easily. This item is currently in stock, so we encourage you to take advantage of our Instant RFQ service to acquire a competitive quote for NSN 5925-00-408-8847 and part number GB3-A2A3A3-5-9. With team members on standby to answer any one of your questions, responses to quote requests or inquiries are completed in as little as 15 minutes.
Take your time to explore our ever-expanding catalogs and you will find that the NSN 5925-00-408-8847 can be found listed under CAGE Code 74193. However, we carry an array of other NSN all of which have been sourced from trusted distributors like Eaton Corp. Get started with the procurement process by requesting a quote on part number GB3-A2A3A3-5-9. Please include all of your part requirements and see how Integrated Electronics Parts can serve as your go-to sourcing solution. For additional questions, call or email us directly; we are ready to help you meet your operational deadlines however necessary.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-408-8847 Item Description: Circuit Breaker | 5925 | 004088847 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Gb3-A2a3a3-5-9 | 2 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 5.990 INCHES MINIMUM AND 6.010 INCHES MAXIMUM |
ADAT | BODY WIDTH | 4.490 INCHES MINIMUM AND 4.510 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 5.115 INCHES MINIMUM AND 5.135 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.256 INCHES MINIMUM AND 0.276 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.583 INCHES MINIMUM AND 4.603 INCHES MAXIMUM |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.177 INCHES MINIMUM AND 0.197 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 4.427 INCHES MINIMUM AND 4.447 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 3 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 480.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 10000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | EXTERNAL AT POLE ONE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 30.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 250.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
CRTK | SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 15.0 AC AND 0.25 DC |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 460.0 AC AND 250.0 DC |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
PKWT | UNPACKAGED UNIT WEIGHT | 4.000 POUNDS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |
Warrantied inventory at competitive prices
Search the world’s largest inventory of electronic components by manufacturer, category or part number
We sell only warrantied and traceable parts
All inventory ready to ship from our sellers
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote